Details for device: Extreme Tube Ride

Violation Summary

Violations Issued This Season: 8 Violations Complied at Time of Inspection: 0
Extreme Tube Ride Violations
Date Cited Description Violation
6/19/2017 Install a proper valve shut off wheel on one of the 3 water pumps currently using a vice grip instead of maunfactures part. Located to the east of the exit pool outside the fence.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
6/19/2017 Properly dig out the footing under screamer slide at the end nearest the exit pool so the support weld joints can be properly inspected.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
6/19/2017 Repair the slippery surface the epoxy fix on the 7th step from the first landing on the left side staircase to top of tower.45-2.13(a)(2)
45-2.13(a)(2)Safe and adequate means to access to and egress from amusement devices and temporary structures shall be provided. Such means of access and egress shall have secure treading and supporting surface free from debris, obstruction, projections and slipping, tripping and other hazards;
6/19/2017 Replace missing handrail on the left stair tower on the first set of stairs going up.45-2.13(c)
45-2.13(c)Stairways and ramps shall be at least 18 inches wide. Stair treads shall be at least nine inches deep exclusive of nosing and the height of rise shall not exceed eight inches. Between any two levels the treads shall be of uniform depth and the risers of uniform height. The slope of ramps shall not exceed one in four. The open sides of stairways, ramps and platforms shall be provided with adequate protection against falling, except as the safe and normal access to the device may otherwise require.
6/19/2017 Replace broken handrail bracket on the first section of the left stair tower on the right side of stairway.45-2.13(c)
45-2.13(c)Stairways and ramps shall be at least 18 inches wide. Stair treads shall be at least nine inches deep exclusive of nosing and the height of rise shall not exceed eight inches. Between any two levels the treads shall be of uniform depth and the risers of uniform height. The slope of ramps shall not exceed one in four. The open sides of stairways, ramps and platforms shall be provided with adequate protection against falling, except as the safe and normal access to the device may otherwise require.
6/19/2017 Repair the (6-7) missing and/or loose spindles in the fencing on the que and exiting areas indicated with orange tape.45-2.13(c)
45-2.13(c)Stairways and ramps shall be at least 18 inches wide. Stair treads shall be at least nine inches deep exclusive of nosing and the height of rise shall not exceed eight inches. Between any two levels the treads shall be of uniform depth and the risers of uniform height. The slope of ramps shall not exceed one in four. The open sides of stairways, ramps and platforms shall be provided with adequate protection against falling, except as the safe and normal access to the device may otherwise require.
6/19/2017 Repair the (2) loose handrails in the exiting part of the pool at the bottom of the slides. They are the outside end handrails on each side.45-2.13(c)
45-2.13(c)Stairways and ramps shall be at least 18 inches wide. Stair treads shall be at least nine inches deep exclusive of nosing and the height of rise shall not exceed eight inches. Between any two levels the treads shall be of uniform depth and the risers of uniform height. The slope of ramps shall not exceed one in four. The open sides of stairways, ramps and platforms shall be provided with adequate protection against falling, except as the safe and normal access to the device may otherwise require.
6/19/2017 Reapir the corroded cover & junction box of the GFI outlet nearest the beginning of the ride side stair tower on the bottom of a support pole.45-2.21(a)
45-2.21(a)General requirement. All electrical wiring, equipment and apparatus used for amusement devices or for lighting shall be installed, operated and maintained in compliance with this Part (rule), Industrial Code Rule 57 High Voltage Proximity, and the National Fire Protection, National Electrical Code, NFPA 70-1999 (NEC-1999).