Details for device: Funhouse

Violation Summary

Violations Issued This Season: 5 Violations Complied at Time of Inspection: 2
Funhouse Violations
Date Cited Description Violation
10/22/2017 jack stands on rear walkway must be either pinned and r-keyed os nut and bolt45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
8/2/2017 Secure stairs properly.45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
9/14/2017 Properly secure fencing to back walkway of ride.45-2.16
45-2.16An amusement device shall not be used or operated while any person is so located as to be endangered by it. Areas in which persons may be so endangered shall be fenced, barricaded or otherwise guarded against public intrusion.
7/25/2017 Fix emergency light by rear exit.45-4.3(d)
45-4.3(d)Emergency lighting. Each building or structure shall be equipped with an emergency lighting system conforming to the requirements of Part 1032, of Title 9 NYCRR Emergency Power and Lighting, of the New York State Uniform Fire Prevention and Building Code, effective January 1, 1984. In addition, the emergency lighting system shall be automatically activated by the operation of the fire and smoke detection system required under subdivision 45-4.3(e) of this Subpart.
7/25/2017 Fix smoke detector near exit.45-4.3(e)
45-4.3(e)Fire and smoke detection system. Each building or structure shall be equipped with a fire and smoke detecting system conforming to the requirements of Section 1060.3, Part 1060, Title 9 NYCRR Fire-and Smoke-Detecting Systems, of the New York State Uniform Fire Prevention and Building Code, effective November 15, 1985. In addition, this system shall have the capability of activating the emergency lighting system required by subdivision 45-4.3(d) of this Subpart.