Details for device: Ferris Wheel

Violation Summary

Violations Issued This Season: 3 Violations Complied at Time of Inspection: 1
Ferris Wheel Violations
Date Cited Description Violation
7/11/2017 Wooden pad under front left dolly is crushing and needs to be replaced45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
7/18/2017 Repair the wooden wire hold down on the side of tub #7 as the wood is broken. Complied at visit45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
7/11/2017 Hair guard bracket on left side of car #4 needs to be re-rivited.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
7/27/2017 (2) Outlets used for lighting are not outdoor rated (need GFCI outlets with covers).45-2.21(a)
45-2.21(a)General requirement. All electrical wiring, equipment and apparatus used for amusement devices or for lighting shall be installed, operated and maintained in compliance with this Part (rule), Industrial Code Rule 57 High Voltage Proximity, and the National Fire Protection, National Electrical Code, NFPA 70-1999 (NEC-1999).