Details for device: Musical Chairs

Violation Summary

Violations Issued This Season: 12 Violations Complied at Time of Inspection: 2
Musical Chairs Violations
Date Cited Description Violation
6/7/2017 Clean bird droppings off of seat #6. Complied at visit45-1.17
45-1.17A suitable number of containers for refuse shall be provided in and around amusement devices, temporary structures, viewing stands and tents. Excessive accumulations of trash or refuse shall be promptly removed. All parts of amusement devices, temporary structures, viewing stands and tents used by passengers or customers shall be maintained in a clean condition.
5/26/2017 Invert right hand side front wirerope thimble on chair 1.45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
5/19/2017 Install wire rope thimble on chair as flagged.45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
9/15/2017 Replace the top safety wire were the chains connect to the sweep arm on Swing #6. Wire protective cover is missing in spots and the wire rope is rusted. DO NOT LOAD UNTIL COMPLIED45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
9/15/2017 Repair the broken loop on the lap bar were the safety chain attaches to lap bar on swing #2. DO NOT LOAD UNTIL FIXED.45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
7/7/2017 Do not load tub 8 until restraint bar is repaired or replaced.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
7/7/2017 Cover edge on tub 9.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
7/7/2017 Cover edge on tub 13.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
4/29/2017 Do not load chair 5 until fiberglass holding bolted restraint chain is repaired.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
4/29/2017 Do not load chair 13 until fiberglass holding bolted restraint chain is repaired.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
6/1/2017 Secure loose wire rope thimbles located on the front wire ropes for swings #3,4 & 9. COMPLIED AT VISIT45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
9/15/2017 Replace the Red electric box cover in the center of the ride, opposite the electric panel box in the center45-2.21(a)
45-2.21(a)General requirement. All electrical wiring, equipment and apparatus used for amusement devices or for lighting shall be installed, operated and maintained in compliance with this Part (rule), Industrial Code Rule 57 High Voltage Proximity, and the National Fire Protection, National Electrical Code, NFPA 70-1999 (NEC-1999).