Skip to Content Skip to Navigation

Amusement Device Detials

The New York State Department of Labor inspects all amusement devices on or before the scheduled start date of an event. Only those devices deemed safe are allowed to operate. Detailed inspection results for each individual device will be posted within two weeks of the event start date.

For more information, look at our Frequently Asked Questions.

Details for device: Slide

Violation Summary

Violations Issued This Season: 6 Violations Complied at Time of Inspection: 5
Slide Violations
Date Cited Description Violation
6/23/2017 The slide was missing a nut on the end of the bolt, bottom right hand side of the slide. Repaired after mentioned.45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
7/25/2017 Install bolt to secure railing.45-1.6(b)
45-1.6(b)Assembly work shall be performed in a proper and workmanlike manner. Parts shall be properly aligned, and shall not be bent, distorted, cut or otherwise injured to force a fit. Parts requiring lubrication shall be lubricated in course of assembly. Fastening and locking devices, such as bolts, cap screws, cotter pins, lock washers, etc. shall be installed where required. Nuts shall be drawn tight, cotter pins shall be spread and lock nuts firmly set.
8/4/2017 Repair the broken hinge for the top handrail located on the stairs near the first lite.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
6/15/2017 Protect the connection point of the slide on the left of the stairs as show with a flag.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
5/5/2017 The white cable in the main power cable to the midway box was cut with exposed conductors. BU staff fixed the issue for the owner.45-2.21(a)
45-2.21(a)General requirement. All electrical wiring, equipment and apparatus used for amusement devices or for lighting shall be installed, operated and maintained in compliance with this Part (rule), Industrial Code Rule 57 High Voltage Proximity, and the National Fire Protection, National Electrical Code, NFPA 70-1999 (NEC-1999).
5/18/2017 Properly set up railing on the upper section of stair case. DO NOT LOAD SLIDE UNTIL COMPLIED. Complied at visit.45-3.7(b)(2)
45-3.7(b)(2)The open sides of each stairway and landing providing access to a slide shall be protected by a railing at least 36 inches in height. Such railing shall be provided with a midrail.

View All Events Listing

Thanks for the feedback! It will help us improve your experience.