Details for device: Slide

Violation Summary

Violations Issued This Season: 2 Violations Complied at Time of Inspection: 0
Slide Violations
Date Cited Description Violation
8/11/2017 Top step of aluminum steps has a crack, left side top step.45-1.6(c)
45-1.6(c)Parts which are excessively worn or which have been materially damaged shall not be used. Close visual inspection of parts shall be made during assembly to discover such wear or damage and immediate inspection of fastening devices shall be made after assembly to assure that they have been properly installed.
8/11/2017 Open wire nuts and taped connections not per NEC, light towers each side of slide.45-2.21(a)
45-2.21(a)General requirement. All electrical wiring, equipment and apparatus used for amusement devices or for lighting shall be installed, operated and maintained in compliance with this Part (rule), Industrial Code Rule 57 High Voltage Proximity, and the National Fire Protection, National Electrical Code, NFPA 70-1999 (NEC-1999).